Bolt Brokers supplies GPT Industries flange isolation kits (also called insulating kits or FIKs) —
isolating/sealing gaskets plus sleeves and washers for electrical isolation, cathodic-protection breaks, and flange-face corrosion control.
Quote-first for contractors and plant buyers across the Western USA.
flange isolation kitsinsulating kitsisolation gasketsGPT insulating kitsPikotek VCSLineBackerType E / Type F
What flange isolation kits do
A complete flange isolation kit seals the joint and electrically isolates one flange from the other.
That matters for cathodic protection systems, dissimilar-metal flanges, and preventing flange-face corrosion in pipelines, waterworks, and plant piping.
GPT builds isolation products from engineered laminates and sealing elements. Components can ship separately or as a matched kit.
As a GPT Industries distributor, Bolt Brokers helps you pick the right series for pressure class, media, and facing — then sources it to the RFQ.
Typical insulating-kit stack for education: gasket between flanges, sleeves on bolts, insulating washers, then steel washers and nuts. Exact materials follow the GPT series you specify.
What’s in a complete insulating kit (FIK)
Isolating / sealing gasket (Type E full-face or Type F ring)
Insulating bolt sleeves (one per bolt/stud)
Insulating washers
Steel backup washers
Optional: single-, double-, or one-piece sleeve/washer sets depending on isolation level needed
Type E vs Type F isolation gaskets
Type E — full face
Retainer extends to the flange outside diameter with holes at the bolt circle. Common on flat-face flanges and where full-face coverage is specified.
Type F — ring style
Retainer sits inside the bolt circle; bolts/studs center the gasket. Widely used on raised-face flanges when a ring gasket is called out.
GPT / Pikotek isolation gasket families we commonly quote
Below is an educational overview of major GPT insulating-gasket lines. Final selection depends on flange class, temperature, media, and drawings.
Brand names are GPT / Pikotek / PSI trademarks; descriptions are rewritten for customer education.
High integrity
Pikotek VCS isolating gaskets / kits
High-strength isolating gasket platform for aggressive services and higher flange classes. Often specified where sealing performance and electrical isolation both matter. Suitable for demanding ANSI / API class work when matched correctly.
Fire-service option
Pikotek VCFS fire-resistant kits
Adds fire-service sealing capability to the VCS platform for applications that require isolation performance plus fire-test considerations. Ask us when fire specs appear on the datasheet.
High temperature
Pikotek VCXT high-temp sets
For elevated-temperature flange isolation where standard laminates may not hold. Useful on load-compromised or heavily bolted connections when the engineer calls for high-temp isolation.
Bore seal
Pikotek VCS-ID inside-diameter seal
VCS-style platform with an internal PTFE seal near the bore for tight sealing against internal pressure and aggressive media. Spec when ID sealing is called out.
Workhorse
LineBacker isolating gaskets / kits
Uses a rectangular “quad” sealing element and groove design to seal and isolate many flange types. Available in Type E or F with single, double, or one-piece sleeve/washer options.
Water service
LineBacker 61 NSF/ANSI 61 options
LineBacker variants certified to drinking-water health-effects criteria where NSF/ANSI 61 compliance is required. Confirm current certification on the specific part before potable-water install.
Low–mid pressure
Pikotek PGE system
Economical GRE-based isolation alternative to older phenolic kits for many Class 150–600 style services. Strong option for dissimilar-metal flanges and flange-face corrosion control when class allows.
Encapsulated
EVOLUTION isolation gaskets
Fully encapsulated isolating gasket design with a thinner profile aimed at easier handling versus thicker legacy stacks. Ask when EVOLUTION is named on the BOM.
Specialty
Related GPT items
We can also quote related GPT hardware when it appears on the same RFQ — strainer-style LineBacker gaskets, coated isolation washers, orifice plates, and accessory lubricants — based on your documents.
Where insulating kits are used
Oil & gas / transmission
Pipeline flange isolation for CP systems, station piping, and high-integrity sealing where isolation gaskets are specified.
Water & wastewater
Waterworks flanges, treatment plants, and potable lines when isolation and approved materials are required.
Dissimilar metals
Break galvanic couples between flange materials that would otherwise corrode at the face.
Plant & industrial
Process piping, terminals, and maintenance replacements — match kit series to the existing standard on the isometric.
RFQ checklist for isolation / insulating kits
Cleaner take-offs get faster quotes. Include as much of the following as you have:
Flange size / NPS and facing (RF, FF, RTJ, etc.)
Pressure class (and standard: ASME, API, etc.)
Gasket style: Type E or Type F
GPT / Pikotek series if known (VCS, LineBacker, PGE, EVOLUTION…)
Sleeve & washer set: single, double, or one-piece
Bolt/stud diameter and count (or bolt circle)
Service media, temperature, and pressure
Quantity and need-by date
Domestic vs import preference
Drawings, isometrics, or manufacturer callouts (PDF/Excel OK)
Also quoting NBG kits, steel couplings, and industrial fasteners on the same job? Send one combined RFQ — we broker the package.
GPT Torque Calculator
Use GPT Industries’ official flange isolation torque resources to size bolt torque for your gasket series,
flange standard, bolt grade, and friction factor. Bolt Brokers links you to the manufacturer tools — always
confirm final values against the project spec and GPT installation instructions.
Select your GPT isolation gasket / kit product family (VCS, LineBacker, PGE, EVOLUTION, etc.).
Enter flange standard, size, and class (ASME B16.5 / B16.47, API 6A, AWWA, etc.).
Confirm bolt grade, lubricant / coefficient of friction, and target bolt stress.
GPT’s published guidance commonly assumes C.o.F. 0.11 for uncoated bolts with Pikolube, about 30% bolt yield for standard gaskets, and about 50% bolt yield for fire-safe service — verify on the tool/table you use.
Tighten in a star pattern (often 30% → 70% → 100%), then a final circular pass per GPT install instructions.
Bolt torque tables (C.o.F. 0.11)
While GPT’s interactive calculator is being updated, use these official manufacturer tables:
ASME B16.5 & B16.47 Series A
Most common pipe flanges — GPT bolt torque table at 0.11 friction factor.
Disclaimer: Torque values depend on bolt condition, lubrication, flange material, and gasket series.
Tables and calculators are provided by GPT Industries for guidance. Bolt Brokers does not replace project engineering —
when in doubt, use GPT max values for fire-risk service or contact us and we’ll help pull the right GPT document for your kit.
A flange isolation kit (insulating kit / FIK) usually includes an isolating gasket plus insulating sleeves and washers so the joint seals while keeping the flanges electrically isolated.
Isolation kit vs insulating gasket — what’s the difference?
The gasket is the sealing/isolating disc between flange faces. A full kit adds the sleeves and washers needed for bolt isolation. Many RFQs mean the complete kit when they say “insulating kit.”
Do you distribute GPT Industries / Pikotek products?
Yes. Bolt Brokers is a GPT Industries distributor and regularly quotes GPT flange isolation gaskets and kits for Western USA jobs.
Can I order gaskets, sleeves, or washers separately?
Often yes — GPT components can be ordered alone or as matched kits. Tell us what the drawing calls for.
How fast can I get a quote?
Send size, class, facing, series if known, and quantity. Clear RFQs are typically turned same business day when suppliers confirm stock.
Where do I find GPT isolation kit bolt torque values?
Use the GPT Torque Calculator section on this page for the official GPT product calculators and C.o.F. 0.11 bolt torque tables (B16.5/B16.47, API 6A, AWWA C207). Always cross-check the install sheet for your exact gasket series.